Recovery and illness warning
A transparent recovery score from last night's HRV, resting heart rate and sleep against your own previous 30 nights, plus an “unusual vitals” warning chosen on the Stanford COVID-19 wearables data. With a survey of open datasets for readiness.
Built from algorithms/recovery/README.md + algorithms/recovery/DATASETS.md
These are the project's working notes, published as written. “You” and “your strap” mean the author and the author's own WHOOP strap; only summary numbers from it appear here, never the recordings.
There is no public dataset with "recovery" labels, so Pulse's recovery is calibrated on your own WHOOP history,
as agreed in docs/algorithms-plan.md.
uv run --with numpy python fit.py /tmp/db/pulse.sqlite # pull the database first (docs/strap-direct.md)
Formula (Metrics.recovery): 100 · sigmoid(b0 + b1·zHRV + b2·zRHR + b3·(hours asleep − 7.5)), where zHRV and
zRHR compare last night with your previous 30 nights (HRV on a log scale). It only uses things Pulse measures
itself from the strap (HRV from beat intervals during the main sleep, resting HR, time asleep), so it works when
WHOOP hasn't scored a sleep, or without WHOOP at all.
Fit: WHOOP's own nightly HRV, resting HR, time asleep and recovery, 336 days with a 30-day baseline. Fitted on the earliest 70 %, tested on the latest 101 days it never saw:
| Mean error | Correlation | Same zone (red < 34 · yellow · green ≥ 67) | |
|---|---|---|---|
| Calibrated | 7.2 points | 0.87 | 81 % |
| Previous fixed formula | 11.2 | 0.80 | 69 % |
| Always your median | 15.6 | – | 54 % |
Coefficients (all days): intercept 0.79, zHRV 0.57, zRHR −0.02, sleep 0.22 per hour. For you, HRV carries almost everything; resting HR adds nothing once HRV is known; each hour of sleep above or below 7.5 h moves the score a little.
Caveat: Pulse's HRV (median of 5-minute RMSSD over the whole sleep) isn't measured exactly like WHOOP's, but the score uses each night relative to your own recent nights, so a constant difference cancels out. Refit as Pulse's own nights build up.
Open datasets (see DATASETS.md)
Starting weights, IFH-Affect (prior.py, 20 Oura users, CC0): the same formula fitted to Oura's readiness
score with HRV and resting HR computed Pulse's way. On each person's latest 30 % of nights: mean error 4.6 points,
r 0.76 (always-median 7.2). Oura weighs resting HR far more than HRV (zHRV 0.03, zRHR −0.14, sleep 0.23). Applied to
your WHOOP history it ranks days reasonably (r 0.65) but on Oura's compressed scale (mean error 16 points), so it is
not used for you: your own WHOOP fit is better. It's kept in RecoveryModel.prior for a user without WHOOP
history.
Illness warning, Stanford COVID-19 wearables (illness.py, 120 people, 7,829 nights, 31 with a usable symptom
date). 36 rules compared (z / robust z / bpm thresholds × 1–3 nights in a row); chosen: the most sensitive rule
with at most ~1 false alarm per 3 months:
| Rule | Caught (days −7…+3 around symptoms) | False alarms |
|---|---|---|
| Resting HR > median + 2 × 1.4826·MAD of the previous 28 nights, 2 nights in a row | 39 % (12 / 31) | 0.35 per 30 nights |
| same, 1 night | 77 % | 1.8 per 30 nights (too noisy) |
| z > 1.5, 2 nights (feasibility check) | 32 % | 0.30 |
On your 343 WHOOP nights it would have fired twice (5 Jan and 5 Aug 2026). In the app: WhoopKit/IllnessWarning.swift,
posted as an "Unusual vitals" notification with not-a-diagnosis wording.
Not used for training: same-day mood/readiness questionnaires (LifeSnaps, PMData, PANAS, Welltory) track overnight physiology only weakly (within-person r ≤ 0.16), so fitting to them would fit noise.
Open datasets for a recovery / readiness model
Research done 2026-11-29. Nobody publishes a "recovery" label, but plenty of open datasets pair nightly HRV / resting HR /
sleep with something that can stand in for one: a device's own readiness score, a daily questionnaire, or an illness
date. Every link below was opened and checked; the open ones were downloaded and tested with feasibility.py.
sh fetch.sh # ≈ 1.2 GB download into data/ (gitignored)
uv run --with numpy --with pandas --with openpyxl python feasibility.py # ≈ 3 min, prints every number quoted below
Short answer
- The physiology works; the daily mood questionnaires barely follow it. Last night's ln-RMSSD and resting HR compared with the person's previous 30 nights predict a device readiness score well (Oura, r ≈ 0.75 on held-out days). They track illness and strain events clearly (resting HR z rises to +0.7 around COVID symptom onset; nightly HRV z is −1.0 on sick days and −1.6 after alcohol). They hardly predict same-day subjective mood, tiredness or readiness (within-person r between −0.05 and +0.16 in five datasets). That matches the sports science literature, where daily HRV relates to subjective wellness weakly and mostly through trends.
- Use these 3:
- IFH-Affect (Oura) as a second target for calibration, next to the user's WHOOP history.
- Stanford COVID-19 Wearables, plus Homekit2020 once registered, to check that the score catches illness.
- LifeSnaps (Fitbit Sense) for nightly temperature and respiration contributors, and as an honest test against self-reports.
- Don't tune to subjective labels. With r ≈ 0.1, any weights fitted to them are noise. Use them only as a sanity check (the sign must come out right).
Ranked table
(a) = useful for building the score (overnight HRV/RHR/sleep/resp/temperature vs a personal baseline). (b) = useful for validating it (does it predict something real). ★★★ is best.
| # | Dataset | Access | Size | Signals (sampling) | Labels | Device | (a) | (b) |
|---|---|---|---|---|---|---|---|---|
| 1 | IFH-Affect: college students, COVID lockdown (Zenodo 10458511) | open, CC0 | 21 people × ≈ 7.8 months ≈ 4 000 nights | Oura nightly RMSSD, lowest/avg HR, temp delta, resp rate, sleep stages; 5-min HR + RMSSD through each sleep; Samsung watch PPG/IMU | Oura readiness score + its contributors (daily); daily PANAS (end of day), weekly/monthly mood scales | Oura ring, Samsung Galaxy Watch | ★★★ | ★★ |
| 2 | Stanford COVID-19 Wearables (Mishra et al. 2020, Nat Biomed Eng) | open download, no licence file (cite the paper) | 120 HR files; 32 COVID-19 cases + 15 other illnesses with dates; weeks to months each | Fitbit/Apple Watch HR every 5–15 s, steps per minute, sleep stages | symptom onset, diagnosis, recovery dates (Supplementary Table 3); daily symptom reports (Table 5) | Fitbit, Apple Watch, Garmin | ★ | ★★★ |
| 3 | LifeSnaps (Zenodo 7229547) | open, CC BY 4.0 | 71 people × ≈ 4 months; 2 475 nights with HRV | Fitbit nightly RMSSD, non-REM HR, resting HR, breathing rate, nightly skin temperature and its variation, SpO2, sleep stages (daily); minute HR / 5-min HRV in the Mongo dump | daily mood EMA (tired / rested / happy / tense …), Fitbit Stress Management Score (device), PANAS/STAI surveys | Fitbit Sense | ★★★ | ★ |
| 4 | Homekit2020 (Evidation flu study; paper, Synapse syn22803188) | Synapse account + data use terms | ≈ 14 M hours of minute-level data (per paper), 4-month study | minute-level Fitbit HR, steps, sleep | PCR-confirmed influenza, daily symptom surveys | Fitbit | ★ | ★★★ |
| 5 | Welltory HRV-COVID19 (GitHub) | open, CC0 repo (README asks for an OSF preprint of any research) | 185 people, 3 245 HRV measurements | beat-to-beat RR of 1–3 min spot checks (phone camera PPG or chest strap), daily wearable summaries (resting HR, sleep) | "How do you feel physically / mood / sleep" (−2..2) right after each measurement; COVID symptom surveys | phone PPG, Polar etc. | ★ | ★★ |
| 6 | mcPHASES (PhysioNet) | credentialed (CITI training + DUA) | 42 people × 3 months (+20 for a second 3 months) | Fitbit HR, HRV, skin temperature, resp rate, sleep, stress score | daily self-reports (sleep quality, stress, mood, cramps…), urine hormones | Fitbit Sense | ★★ | ★★ |
| 7 | PMData (Simula, OSF vx4bk) | open, CC BY 4.0 | 16 people × 5 months; 1 747 wellness reports | Fitbit HR every 5–15 s, nightly resting HR + sleep score, sleep stages, steps; no HRV | PMSys morning readiness (0–10), fatigue, soreness, sleep quality, mood, stress; sRPE training load, injuries | Fitbit Versa 2 | ★ | ★★ |
| 8 | Rao 2023 Sjögren's / SLE / healthy (Zenodo 8018238) | open, CC BY 4.0 | 296 people × 1 month; 3 950 matched days | Fitbit daily features: asleep HR mean, resting HR, sleep minutes, steps; no HRV | daily tiredness, pain, day rating; weekly fatigue scales | Fitbit | ★ | ★ |
| 9 | Luo 2020 fatigue (Zenodo 4266157) | open, CC BY 4.0 | 28 people, 973 days (405 with both sensors and reports) | 1-min HR, HRV, skin temperature, respiration, activity (armband) | evening fatigue 1–10, physical/mental exhaustion | Biovotion Everion armband | ★★ | ★ |
| 10 | 1000 days of HRV (GitHub) | public repo, no licence: for personal analysis only, ask before redistributing | 1 person × 1 057 days | Polar nightly RMSSD; 1–2 min morning RMSSD; training load | diary events (sick, alcohol, stress, travel…) | Polar Grit X Pro, HRV4Training | ★ | ★★ |
| 11 | TILES-2018 / 2019 (tiles-data.isi.edu) | account + agreement | 212 hospital workers × 10 weeks (2018); 57 ICU residents (2019) | Fitbit HR/sleep; OMsignal ECG shirt HR/HRV/breathing during shifts only | twice-daily stress, anxiety, affect, fatigue, job performance | Fitbit Charge 2, OMsignal | ★ | ★ |
| 12 | SoccerMon (Simula, Zenodo 10033832) | open, CC BY 4.0 | 2 elite women's teams × 2 seasons | GPS only (subjective file 0.7 MB; GPS 23–31 GB); no HR/HRV | PMSys daily readiness, fatigue, soreness, sleep, mood, stress, illness, injury | STATSports APEX | – | ★ (label behaviour only) |
| 13 | In-situ HRV + sleep diaries (figshare 28509740) | open, CC BY | 49 people × 4 weeks | 5-min HR, IBI-derived RMSSD/SDNN/LF/HF, acc, light (smartwatch, 10 Hz raw is 19.7 GB) | sleep diary (times only), PHQ-9 / GAD-7 / ISI every 2 weeks | smartwatch | ★ | – |
| 14 | GLOBEM (PhysioNet) | credentialed | ≈ 500 students, 4 yearly cohorts | Fitbit steps + sleep, phone sensing | weekly PHQ-4, depression | Fitbit | – | ★ |
| 15 | MMASH (PhysioNet) | open | 22 people × 24 h | beat-to-beat RR, actigraphy, sleep | STAI, PSQI, cortisol/melatonin | Polar H7, ActiGraph | – (one night) | – |
Checked and rejected:
- Kaggle "Whoop_Fitness_Dataset [100K]": Kaggle labels it synthetic, so don't use it for anything.
- Lockdown orthostatic HRV (Zenodo 4058116): 95 people, 11 600 supine/standing RR files. The well-being scores the paper reports aren't in the archive.
- Table-tennis HRV/ACWR trial (Zenodo 21343993): HRV and readiness only weekly; looks too clean (17 of 24 outcomes significant).
- TemPredict (Oura), Scripps DETECT, Mount Sinai Warrior Watch, Fitbit COVID: data only on request.
- NSRR (SHHS etc.): single-night PSG with morning questionnaires, credentialed. Not verified this session (sleepdata.org was down for maintenance).
- Kaggle "Oura Health Data analysis (one year)": one person, Kaggle login. Possible later as an extra readiness sanity check.
Feasibility (downloaded data, feasibility.py)
Method: for each person, z = (last night − mean of the previous 7–30 nights) / SD of those nights. HRV is on a log
scale, as Metrics.recovery already does. r_within is the repeated-measures correlation (each label centred on
the person's own mean), with a 95 % person-bootstrap CI. That is the question a personal-baseline score answers.
"Recovered" means high z_lnHRV and low z_RHR; z_HRV−RHR = z_lnHRV − z_RHR.
| Dataset | Usable person-days (people) | Label | z_lnHRV | z_RHR | z_HRV−RHR |
|---|---|---|---|---|---|
| IFH-Affect | 3 834 (21) | Oura readiness | +0.38 [0.30, 0.45] | −0.46 [−0.52, −0.41] | +0.46 [0.39, 0.53] |
| IFH-Affect | 3 187 (21) | PANAS positive affect (evening) | +0.03 [−0.01, 0.06] | −0.03 | +0.03 |
| LifeSnaps | 988–1 248 (27–30) | EMA "tired" (1 = yes) | −0.04 [−0.11, 0.03] | +0.04 | −0.05 |
| LifeSnaps | EMA "rested/relaxed" | +0.02 | −0.03 | +0.03 | |
| LifeSnaps | Fitbit Stress Management Score (device; uses HRV) | +0.29 [0.20, 0.36] | −0.24 | +0.29 | |
| Welltory | 648 (18) | "How do you feel physically?" right after a morning spot check | +0.11 [0.01, 0.25] | −0.15 [−0.26, −0.04] | +0.16 [0.06, 0.29] |
| Welltory | 659 (20) | "How did you sleep?" | +0.09 | −0.15 | +0.14 [0.04, 0.25] |
| PMData | 1 354 (14) | PMSys readiness 0–10 (morning) | no HRV | −0.03 (sleep RHR); −0.10 [−0.21, −0.01] (Fitbit day RHR) | – |
| PMData | 1 388 (15) | fatigue / soreness / mood / stress | no HRV | −0.06 … +0.05, all CIs span 0 | – |
| Rao 2023 | 3 313 (167) | daily tiredness | no HRV | +0.03 [−0.01, 0.06] | – |
| Luo 2020 | 204 (5) | evening fatigue 1–10 | −0.03 | −0.02 | 0.00; but z_temp +0.17, z_resp +0.16 (higher at night → more fatigue) |
Reproducing a device score (IFH-Affect: fitted on each person's first 70 % of days, tested on the last 30 %, as
fit.py does with WHOOP; linear model on the 0–100 score):
| Inputs | Test days | r | MAE | Always-median MAE |
|---|---|---|---|---|
| Oura's own nightly RMSSD and lowest HR, + sleep hours | 1 140 | 0.73 | 4.8 | 7.1 |
| Pulse's definition from Oura's 5-min series (median 5-min RMSSD, 5th pct HR), + sleep | 1 137 | 0.74 | 4.7 | 7.1 |
| … + temperature z + respiratory-rate z | 501 | 0.76 | 4.5 | 6.9 |
Coefficients (points per z): HRV +0.6, RHR −2.6, sleep +4.1 per hour, temperature −0.8. Oura leans on resting HR,
while WHOOP leans on HRV for this user (README.md: zHRV 0.57, zRHR −0.02). So a population target can't settle the
weights; it only shows that a transparent baseline formula gets close to a commercial score.
Illness (Stanford, 41 people with a symptom date). Overnight resting HR = 10th percentile of 00–06 h heart rate during minutes with zero steps, z vs the previous 28 nights:
| Days vs symptom onset | −28…−15 | −14…−8 | −7…−1 | 0…+3 | +4…+10 |
|---|---|---|---|---|---|
| mean z_RHR | +0.03 | −0.07 | +0.34 | +0.69 | −0.08 |
| nights with z > 1.5 | 10 % | 3 % | 18 % | 27 % | 10 % |
A simple alarm (2 nights in a row with z_RHR > 1.5) fires in days −7…+3 for 31 % of people (11/35), and in 12 % of other 11-night windows. That's real signal but low sensitivity from RHR alone, in line with the paper. HRV, temperature and respiration should raise it; the literature (TemPredict, Natarajan 2020) finds temperature and respiration the strongest illness markers.
Events, one person (1000 days of HRV): nightly ln-RMSSD z on diary days: sick −1.04 (24 nights), alcohol −1.64 (11), hard exercise −0.90 (9), stress −0.22 (18), travel 0.00, no event 0.00. The morning 1–2 min reading correlates only r = 0.38 with the nightly value, which supports Pulse using the whole night.
Recommendation: what to do with which
- IFH-Affect: second calibration target and a check on the formula.
- Its 5-min sleep series lets us compute exactly Pulse's nightly HRV and RHR, then fit the same
100·sigmoid(b0 + b1·zHRV + b2·zRHR + b3·sleep (+ b4·zTemp + b5·zResp))against Oura readiness. - Report it next to the WHOOP fit (
fit.py). - Keep the WHOOP-fitted weights for the user (personal, same strap), and use the Oura fit to set sensible population defaults for a new user with < 30 nights. It also shows how much temperature and respiration add, before we decode skin temperature from the strap.
- Its 5-min sleep series lets us compute exactly Pulse's nightly HRV and RHR, then fit the same
- Stanford COVID-19 (now) + Homekit2020 (register on Synapse): the validation of "it predicts something real".
- Metric: share of illness episodes where the score drops into red (or z_RHR/z_temp alarms) in days −3…+3, against the false-alarm rate in healthy windows (12 % baseline above).
- Add this as a test in
fit.py, so a re-fit that improves WHOOP agreement but loses illness detection is visible.
- LifeSnaps: temperature and respiration contributors, plus the honest self-report check.
- Fitbit gives nightly skin-temperature deviation and breathing rate for 71 people. That is enough to set the baseline rules (z thresholds, how fast the baseline adapts) for the two contributors Pulse doesn't have yet.
- Its mood EMA (with PMData readiness and Welltory "how do you feel") is the regression test: the score must correlate with the right sign, but don't fit to it.
Not worth more time: PMData and Rao 2023 (no HRV, labels barely move with RHR), Luo 2020 (5 usable people), SoccerMon (no physiology).
Published methods we can implement transparently
| Method | What it does | Use in Pulse |
|---|---|---|
| Plews et al. 2012 (Eur J Appl Physiol) & 2013 (Sports Med), elite endurance athletes | daily ln-RMSSD is noisy; use the 7-day rolling mean and its coefficient of variation; a falling mean or rising CV flags maladaptation | show a 7-day ln-RMSSD trend next to the daily score |
| Smallest worthwhile change (Buchheit 2014, Front Physiol; Plews 2013) | "normal" band = baseline mean ± 0.5 × SD of the person's ln-RMSSD; outside it is a meaningful change | green/yellow/red bands from the person's own SD instead of fixed cut-offs |
| HRV-guided training: Kiviniemi 2007 (EJAP), Vesterinen 2016 (MSSE), Javaloyes 2019 (IJSPP), Nuuttila 2022 (nocturnal) | train hard only when the 7-day (or morning) ln-RMSSD is inside the SWC band of a 4-week baseline; otherwise go easy | the "should I go hard today" recommendation, with a published rule behind it |
| Flatt & Esco 2016 (weekly ln-RMSSD mean and CV) | weekly mean and CV of ln-RMSSD in team-sport athletes | weekly trend card |
| HRV4Training / Altini: normal range | 7-day vs 60-day baseline with an SD band (published method notes) | same idea as SWC; a long baseline for slow changes |
| Garmin HRV Status (Firstbeat) | 7-day average HRV vs a personal baseline range built over ~3 weeks: balanced / unbalanced / low | wording and needs ≥ 1 week of nights, ~3 weeks for a stable baseline |
| Oura Readiness contributors (Oura) | RHR vs usual, HRV balance (recent vs long-term), body temperature vs usual, recovery index (how early in the night HR reaches its low), sleep, sleep balance (2 weeks), previous-day activity, activity balance | template for a contributor breakdown; "recovery index" is easy from strap HR |
| Illness detection: Mishra 2020 (RHR-Diff, CuSum on overnight RHR), Quer 2021 Nat Med (DETECT: RHR, sleep, steps), Mason 2022 Sci Rep (TemPredict: temperature), Natarajan 2020 npj Digit Med (Fitbit resp rate, HRV, RHR) | sustained rise of overnight RHR / temperature / respiration vs personal baseline | separate "possible illness" flag that overrides a green score |
| Hooper index (Hooper & Mackinnon 1995): fatigue, stress, soreness, sleep, each 1–7 | standard athlete self-report | if we ever add a 4-tap morning check-in, use these items so our labels match the literature (and PMData/SoccerMon) |
Download steps
fetch.sh does all of this. Per dataset:
- IFH-Affect (only the Oura + EMA CSVs, ≈ 19 MB, out of an 8.6 GB zip, via HTTP range requests):
uv run --with remotezip python -c "from remotezip import RemoteZip; z=RemoteZip('https://zenodo.org/api/records/10458511/files/ifh_affect.zip/content'); [z.extract(i) for i in z.infolist() if ('/oura/' in i.filename or '/ema/' in i.filename) and not i.filename.endswith('/')]" - LifeSnaps (615 MB zip; we keep the 32 MB of CSVs and skip the 9.7 GB
fitbit.bson):curl -L -o rais_anonymized.zip https://zenodo.org/api/records/7229547/files/rais_anonymized.zip/content && unzip rais_anonymized.zip 'rais_anonymized/csv_rais_anonymized/*' 'rais_anonymized/scored_surveys/*' - Stanford COVID-19 (378 MB zip, 3.4 GB unzipped):
curl -LO https://storage.googleapis.com/gbsc-gcp-project-ipop_public/COVID-19/COVID-19-Wearables.zipplus the illness dates in the paper's Supplementary Tables:curl -L -o mishra2020_supp_table.xlsx 'https://static-content.springer.com/esm/art%3A10.1038%2Fs41551-020-00640-6/MediaObjects/41551_2020_640_MOESM3_ESM.xlsx' - Welltory:
curl -LO https://raw.githubusercontent.com/Welltory/hrv-covid19/master/data/hrv_measurements.csv(andparticipants,surveys,wearables,sleep). - PMData: the whole set is
pmdata.zip(1.4 GB) on datasets.simula.no/pmdata.fetch.shinstead pulls only the per-personwellness.csv,srpe.csv,sleep_score.csv,resting_heart_rate.jsonandsleep.jsonthrough the OSF API (nodevx4bk, 9 MB). - Zenodo records (Luo 4266157 = 93 MB, Rao 8018238 = 10 MB, SoccerMon
subjective.zip10033832):curl -s https://zenodo.org/api/records/<id> | python3 -c 'import json,sys;[print(f["links"]["self"]) for f in json.load(sys.stdin)["files"]]' | xargs -n1 curl -LOJ - In-situ HRV:
curl -L -o sensor_hrv_filtered.csv https://ndownloader.figshare.com/files/52669385(survey 52669394, sleep diary 52669397). - Homekit2020: create a Synapse account, accept the terms on syn22803188, then
pip install synapseclient && synapse get -r syn22803188. - mcPHASES, GLOBEM: PhysioNet credentialing (ID check + CITI "Data or Specimens Only Research"), sign the DUA, then
wget -r -N -c -np --user <you> --ask-password https://physionet.org/files/mcphases/1.0.1/. - TILES: sign in at tiles-data.isi.edu and accept the agreement, then download from the site.
Caveats
- Device nightly HRV (Oura, Fitbit, Polar) isn't Pulse's HRV; only z-scores vs the person's own baseline are compared, so constant offsets cancel. IFH-Affect is the one set where Pulse's exact definition can be recomputed.
- Readiness scores from Oura and Fitbit use HRV and RHR themselves, so agreeing with them proves "our formula behaves like theirs", not "our formula predicts how you feel". The illness and event datasets are the stronger evidence.
- Label timing matters, and was checked: LifeSnaps and IFH-Affect results stay near zero with the HRV night shifted ±1 day. IFH-Affect EMAs are submitted 22:00–03:00 and count for the day before.
- Small numbers: Welltory 18 people, Luo 5, the single-person diary 1. Treat those as direction only.
Model files
Generated by this algorithm's train.py and copied from the repository at build time. More on the Our data page.
-
coefficients.json 161 Balgorithms/recovery/coefficients.json
The recovery formula's four coefficients, fitted on the author's 336 days of WHOOP history (parameters only, no data)
sha256 f47c4ff1ac2c8aa2…
-
prior.json 203 Balgorithms/recovery/prior.json
Starting weights for a user without WHOOP history, fitted on IFH-Affect (Oura readiness, 20 people)
sha256 4c4d4baf08d2ce57…
-
illness.json 5.3 KBalgorithms/recovery/illness.json
All 36 illness-warning rules compared on the Stanford COVID-19 data, with sensitivity and false alarms
sha256 c22ad30a1a9f1612…
References
- Mishra T et al. Pre-symptomatic detection of COVID-19 from smartwatch data. Nat Biomed Eng 4:1208–1220 (2020)
- Labbaf S et al. Data from: physiological and emotional assessment of college students using wearable and mobile devices (IFH-Affect, CC0)
- Yfantidou S et al. LifeSnaps, a 4-month multi-modal dataset capturing unobtrusive snapshots of our lives in the wild. Sci Data 9:663 (2022)
- Thambawita V et al. PMData: a sports logging dataset. MMSys 2020
- Welltory HRV-COVID19 dataset (GitHub, CC0)
- Plews DJ et al. Heart rate variability in elite triathletes, is variation in variability the key to effective training? Eur J Appl Physiol (2012)
- Plews DJ et al. Training adaptation and heart rate variability in elite endurance athletes. Sports Med (2013)
- Buchheit M. Monitoring training status with HR measures: do all roads lead to Rome? Front Physiol 5:73 (2014)
- Kiviniemi AM et al. Endurance training guided individually by daily heart rate variability measurements. Eur J Appl Physiol (2007)
- Quer G et al. Wearable sensor data and self-reported symptoms for COVID-19 detection. Nat Med 27:73–77 (2021)
- Natarajan A et al. Assessment of physiological signs associated with COVID-19 measured using wearable devices. npj Digit Med 3:156 (2020)
- Mason AE et al. Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict Study. Sci Rep 12:3463 (2022)
- Oura: readiness score contributors